What is the actual structural condition of existing quay walls?

Just how (un)safe are existing quay walls structurally? And how can we predict how quay walls will move in the future, when risks will arise and measures will therefore need to be taken? These are important questions when it comes to managing and maintaining quay walls.

Gemeente Amsterdam hopes to gain insight into this through an innovative proof load test. The test is being carried out at a test site in Amstelkwartier II and is intended to produce a reliable calculation model that gives a realistic picture of the actual structural condition of quay walls. This will enable the municipality to take the right measures in good time and prevent sections of quay from being condemned unnecessarily. This project relies on monitoring with smart sensors as an essential element.
A major and complex challenge
Amsterdam has dozens of kilometres of quay wall that have reached the end of their service life and are in poor condition. Given their poor condition, measures need to be taken quickly, but what measures are needed for all those kilometres of quay wall? And what is the actual state of the structural safety of the quays? Gemeente Amsterdam faces the major and complex challenge of safeguarding safety, accessibility and quality of life in Amsterdam in the short term, while also building up its knowledge of the condition of the quay walls.

A representative test area
A design and construction team has been formed to carry out the proof load test. The test was prepared by AMS institute (Advanced Metropolitan Solutions), a collaboration between various knowledge institutes, including TU Delft. Iv-Infra is involved in the test for its expertise and experience in smart sensors and measurements, as well as its structural knowledge of quay structures. The quay wall at the Overamstel harbour basin was selected as the test location.
Dividing the quay into sections
The section of quay wall being used for this test is approximately 40 metres long. The proof load test consists of several tests. To assess the effect of each test separately, the quay wall has been divided into four comparable sections. The quay wall has literally been sawn in half to create sections, each approximately 6.5 metres long. There is a gap of about one metre between each section.
The quay wall consists of four rows of vertical piles and a raking pile. In two of the four test sections, one row of piles has been cut through to simulate different situations. In addition, the raking pile has been removed from all sections. Cutting through the raking piles reduces the horizontal strength of the quay wall. This was done to make the quay wall more representative of the quays in the city centre. The older quay walls in the city centre generally do not have raking piles.
Real-time insight with smart sensors
Divers have fitted dozens of smart sensors to all the underwater piles, the pile cap and the gravity wall at the front. These sensors have been positioned at carefully selected strategic locations. In addition to the quay structure, the horizontal ground deformation behind the quay, the water level and pore water pressure are measured during the proof load test. This provides a detailed, real-time picture of the behaviour and deformation of the quay wall and the entire soil mass behind it.
For this test, inclinometers attached to the existing piles are being used to measure their tilt during the proof load test. Tilt sensors are also being used to measure rotation of the quay wall. Settlement is measured using prisms and an inclinometer tube. Standpipes and pore pressure sensors are used to measure the groundwater level and pressure. Special vibration monitoring systems are used to measure vibrations, and buildings in the surrounding area have been fitted with levelling bolts. During proof loading, crack gauges show the distance between two points, making it possible to see whether the quay moves as a single unit or whether individual components deform separately. .A robotic total station measures the absolute deformation of the quay wall. All these sensors provide valuable real-time information, which is collected automatically and presented on a single central platform.
Adding ballast
Before the proof load test, TU Delft developed a calculation model and carried out simulation calculations for the test. It also calculated the load at which the quay wall should move forwards by a given number of millimetres. To test this in practice and establish the surcharge at which the quay wall starts to move, and exactly how it moves, progressively more weight is added during the test. This continues until the displacement is such that, theoretically, the quay wall would fail in a controlled manner. The expectation is that the quays will deform by 30 to 70 centimetres. The calculated breaking point is at 30 to 40 centimetres: the point at which the quay wall and the piles fail.
A different situation is being simulated in each test section. For example, the ballast is placed at varying distances from the quay, the depth of the bed is varied, and the effect with and without tree roots is examined. A test is also being carried out on individual piles to measure the horizontal resistance of a single pile. The proof load tests are now well under way. The data obtained from the tests will provide an essential basis for developing the new calculation model.
Question about this story? Ask your question
Keep following this
Get an email when a new story is published. No account needed.
- SubjectRoad construction