Tunnel ventilation and fire safety start with an effective ventilation system
Text Lieke Bousema Image Kingspan Light + Air

Fire and smoke in a tunnel pose a serious danger. Toxic substances and high temperatures often make escape difficult. A fire also consumes all the oxygen in the tunnel, making it difficult for firefighters to reach the scene. “By installing jet fans, escape doors and pressurisation systems in the right places, these challenges can be tackled effectively and people can escape safely,” says Stan Veldpaus, Project Adviser, Smoke Control Systems at Kingspan Light + Air. “Emergency services can also approach the fire with the wind at their backs.” Kingspan Light + Air is happy to act as a knowledge partner on these projects. It can also supply, install and maintain the systems required.
No new tunnels are currently being built in the Netherlands, says Veldpaus. “The Blankenburgverbinding near Rotterdam was recently completed, making it the latest new tunnel to open. However, there is a substantial renovation programme ahead. Tunnels across the country are due for renovation, requiring the structures to be maintained and the tunnel technical systems upgraded. Many of these tunnels are owned by Rijkswaterstaat, which works with major contractors that we are happy to support. By getting involved at an early stage, we can provide even better advice on the right systems and replacement approach.”

Jet fans and pressurisation systems
Kingspan Light + Air’s tunnel ventilation systems fall into two categories: longitudinal ventilation systems (jet fans) for tunnel ventilation, and pressurisation systems for the cross-passage or central tunnel duct. “Longitudinal ventilation systems provide fresh air, ensuring that people can remain in the tunnel in healthy conditions,” says Veldpaus. “In most cases, the system must also serve as a fire safety installation, giving people in the tunnel more time to escape in the event of a fire. It also allows firefighters to approach the fire ‘safely’, with the wind at their backs, enabling them to tackle it more quickly and limit damage to the tunnel.” The pressurisation system keeps smoke out of the cross-passage or central tunnel duct, ensuring a safe escape route. “The key here is to ensure that the airflow is not too strong. People must be able to escape against the direction of ventilation, and the escape doors must be easy to open.”
Retaining existing infrastructure
Existing tunnels already contain extensive electrical cabling and switchgear, much of which can be retained, says Veldpaus, provided that the new fans have the same power rating. “If more power is needed or desired, it may be advisable, for example, to install additional fans at strategic locations. This allows you to meet the required ventilation regime precisely, without having to modify the infrastructure for every fan.” This helps Kingspan Light + Air address one of the key challenges of tunnel renovation: time.

Coordinating the work effectively
“One challenge in tunnel renovations is completing all the work to a high standard and as quickly as possible,” says Veldpaus. “Closing a tunnel causes major disruption to traffic in the surrounding area. That makes it essential to complete and test all the work as efficiently and quickly as possible. Careful coordination is crucial. For example, the new asphalt must be laid before the new fans are installed and commissioned. If the order is reversed, the fans will already be dirty by the time the tunnel is handed over. Many other details also require careful coordination and technical expertise.”
Low power consumption and noise levels
As jet fans are also used for routine tunnel ventilation, it is important that they do not consume too much power, Veldpaus stresses. “Demand-controlled ventilation using variable frequency drives and/or intelligent zoning can play an important role here. The fan’s position (installation efficiency) and size are also important, and we are happy to advise on these at an early stage.” Kingspan Light + Air offers a wide range of attenuators to keep noise under control, while sensors prevent the motor from overheating during standard operation. A Factory Acceptance Test (FAT) is used to check all the technical specifications with the client, after which the fans are installed just in time. “To prevent fans from falling from the ceiling, a structural calculation is always carried out in advance in collaboration with the lead structural engineer. Generous safety margins are always incorporated. Such measures are essential, particularly in rail tunnels, where significant dynamic forces occur.” Safety cables are often fitted as an additional precaution. “We also recommend automatic vibration monitoring, which can identify potential suspension problems in good time. Given the polluting and corrosive conditions in rail and road tunnels, it is essential to select the right materials for all components and fixings.”
Strong project references
Kingspan Light + Air has delivered several notable tunnel projects. It installed a ventilation system with jet fans and a pressurisation system in the new Spaandammertunnel in Amsterdam. It also renewed the ventilation system in the Schipholspoortunnel and will shortly begin a like-for-like replacement of the jet fans in the Hubertustunnel, in line with current regulations. “The jet fans in the Hubertustunnel date from 2007 and are being replaced as part of a larger renovation,” says Veldpaus. “For the past five years, installations have had to meet efficiency class IE3. This requires energy-efficient fans, which in this case means a larger required installation size (diameter). A higher thrust force has also been chosen to further improve performance. Fortunately, there is enough room for this project, allowing the existing infrastructure to be retained sustainably. We look for the optimum solution in every project.”