Computational Fluid Dynamics: computing power helps keep tunnels safe

Effective Smoke and Heat Extraction is vital for tunnels, so that in an emergency road users can escape from the tunnel safely and emergency services can gain safe access. Colt International BV provides smoke control solutions for road, rail and metro tunnels.
They design and supply the complete range of smoke control systems. These may include tunnel ventilation systems that work by moving air, through extraction and/or jet fans, and by pressurisation in stairwells and escape routes. Calculations are needed to ensure that an installation is fit for purpose. A ProTuVem calculation is generally required as a first step, and provides a good initial indication. Colt then validates the ProTuVem designs using CFD, or ‘Computational Fluid Dynamics’.

Design optimisation
CFD simulations make it possible to predict more accurately how effective a tunnel ventilation system and pressurisation installation will be. CFD can also be used to identify potential improvements and/or system optimisations. One example is the fire-resistant cladding in the tunnel, as described by Promat / Etex, and its associated safety benefits. Colt International BV considers CFD the best method currently available for predicting (air)flows and energy transfer in situations that do not yet exist. Carrying out this work at an early stage eliminates the need for costly practical tests.
Reliable CFD calculations make it possible to meet safety requirements for a tunnel ventilation design more quickly. Using CFD also makes the certification of a fire safety system easier and faster. A fire safety system required by or pursuant to law must have an inspection certificate issued by an ISO17020 type A accredited inspection body. The body assesses the derived objective. This assessment can be carried out during the design phase, based on the CFD results. This considerably shortens the time needed to obtain the certificate.

In practice
Vialis BV and Van Hattum en Blankenvoort BV, both part of Koninklijke VolkerWessels, are carrying out the fit-out and installing the tunnel technical systems for Tunnel Delft, the second phase of Delft NS station. In 2025, the entire tunnel, phases 1 and 2, will open to rail traffic between Den Haag and Rotterdam. Colt International BV has been appointed to provide fire safety in the tunnels and at the station, and is closely involved in installing the station’s smoke control system, the ventilation system in the tunnels and the pressurisation systems in the emergency stairwells. CFD has also been used here to predict, through simulations, the effect of airflows in the tunnels and the station in the event of a fire.
Question about this story? Ask your question
Keep following this
Get an email when a new story is published. No account needed.
- ThemeUnderground construction
- SubjectBridge construction