Rapid pile testing is gaining popularity

There is growing interest in carrying out load tests as part of foundation design. According to Rob van Dorp of Allnamics, significant savings can be achieved by designing foundations more efficiently than the specified standards require. However, the design must then be verified in accordance with NPR 7201 (Netherlands Practical Guideline). Allnamics has developed a unique and efficient method for rapid pile testing, known as StatRapid.
Allnamics carries out pile tests to establish the quality and suitability of a foundation pile. “These range from tests to determine load-bearing capacity to tests that analyse pile-soil behaviour or check the pile itself,” says Van Dorp. “In effect, we check whether what has been designed in theory has also been achieved in practice at that location.”

StatRapid load testing
“In addition to static load testing, so-called dynamic load testing was developed in the 1960s,” says Marcel Bielefeld of Allnamics. “At the time, it was used mainly to test large piles for offshore structures. It has since become common practice worldwide for all pile types. However, dynamic load testing has a number of limitations and uncertainties. The Rapid Load Test is a quasi-static test that combines the benefits of both methods: the reliability of static load testing with the speed and cost savings of dynamic testing, while raw test results are available on site immediately. It is an efficient, scalable method for carrying out rapid pile tests. This testing method is now accepted worldwide and incorporated into many codes and standards, including Eurocode and ASTM.” Van Dorp adds: “Some of our StatRapid units are therefore based in Asia. An example project in the Netherlands is Spuikwartier in The Hague, while in Belgium this type of load testing was used during construction of the new road bridge in the port of Zeebrugge.”
NPR 7201 (Netherlands Practical Guideline) specifies several classes of load tests. “A Class A test was carried out in The Hague, which means the pile was fitted with a load cell, displacement gauges and strain sensors,” Van Dorp explains. “This enabled the design factors to be determined, allowing the foundation structure to be designed considerably lighter than required by the standard. We tested four trial piles using our StatRapid and were able to verify the optimised design. This resulted in a foundation structure with fewer and shorter piles. The most common pile tests, however, are Types C and D, which check, with or without StatRapid, whether the pile’s behaviour meets the design requirements.”
Question about this story? Ask your question
Keep following this
Get an email when a new story is published. No account needed.
- ThemeUnderground construction
- SubjectBouwMat