Bar anchors tailored to geotechnical requirements
Text Roel van GilsImage ANP-Systems

Groundwater pressure beneath the tunnel floor caused one of the tunnel sections of the Prinses Margriettunnel on the A7 to rise in December 2022. Further investigation revealed that a number of tension piles had failed. Rijkswaterstaat therefore decided to renew the entire foundation with more than 1,050 new tension piles from ANP-Systems. The SAS bar anchor system used here is ideally suited to this type of project. We spoke to Remco van der Voorden and Henry Verdaasdonk of ANP-Systems.
At the end of January 2023, ANP-Systems was contacted by Volker Staal en Funderingen to ask whether the SAS bar anchor system was suitable for use as a tension bar in the foundation repair work on the Prinses Margriettunnel. “That was effectively the starting point for an intensive period of several months in which we worked together to find the right solution and finalise the details for the new tension piles,” says Henry. “We discussed issues such as design life, corrosion protection methods, resistance to dynamic loads and connection details between the bar and the floor. In the meantime, we also supplied a number of trial piles to test the local geotechnical load-bearing capacity.”
Screwable bar anchor
The SAS bar anchor system is a well-known product in geotechnical engineering and is widely used, among other applications, for anchor piles and wall and ground anchors. “The bar anchor has a coarse ribbed profile that at first glance resembles a reinforcing bar. The key difference is that the ribs are oriented so that the SAS bar anchor can be screwed in along its entire length. We offer several steel grades for geotechnical applications, all specifically engineered for this purpose. There is a very wide range of sizes, along with a variety of matching accessories. The bars can be supplied with double corrosion protection or electrical insulation if required,” explains Remco.

Project-specific solutions
ANP-Systems can also provide additional project-specific solutions. “For this project, the bars are fitted with a plastic sheath over the top 4 metres, to prevent bonding with the surrounding soil and to provide capacity to resist lateral movement of the pile.”
Because of the continuous groundwater pressure, the contractor is using a specific drilling technique. Henry explains: “The borehole is sealed each time with a valve. This system leaves only limited space for inserting the Ø63.5 mm SAS bar anchor. Working with our factory in Germany, we modified several components to suit the planned drilling technique. Through this collaborative process, we arrived at the optimum design.”
Reliable availability
ANP-Systems is supplying the SAS bar anchor system in stages. The foundation repair work is also being carried out in stages, as part of the Prinses Margriettunnel remains in use. “As the design was not yet finalised during the first phase, we also supplied a batch of extra-long bar anchors. Transporting 30-metre-long bars by road is quite an undertaking,” Henry points out.
In addition, quantities were reserved in production rolling schedules in advance, in consultation with the project team, to ensure reliable availability.
ANP-Systems has now supplied around 680 SAS bar anchors, with deliveries continuing until the third quarter of 2024. “ANP-Systems’ Benelux representative can draw directly on stock in Austria and Germany or, as in this case, liaise directly with the factory for production from a rolling schedule.”
Question about this story? Ask your question
Who worked on Prinses Margriettunnel
- Tension pilesANP-SystemsIn this story
- companyVolker Staal en FunderingenIn this story
Keep following this
Get an email when a new story is published. No account needed.
- ProjectPrinses Margriettunnel
- ThemeUnderground construction
- SubjectNews
- CompanyANP-Systems
- CompanyVolker Staal en Funderingen