BouwMat

Wide Slab Floor Coupling Reinforcement System

Wide Slab Floor Coupling Reinforcement System

S&P C-Laminate LM combined with S&P Resin 220HP epoxy adhesive is the solution for suspect wide slab floors. The system has been fully tested and can be installed with very little disruption.

Following the collapse of the car park in Eindhoven, we brought together our international knowledge and experience and set out to find a suitable solution. As a manufacturer and supplier of carbon fibre-based materials, we are close to the market and are an independent partner for all structural engineers.

Our S&P C-Laminate has been used successfully for 25 years in strengthening measures for concrete structures in the broadest sense. Applications range from openings, voids and spans to reducing the effects of existing reinforcement corrosion in civil engineering structures. Our carbon reinforcement is also used in repairs to cantilevered balconies and walkways, and to strengthen masonry in earthquake-prone areas.

The S&P Wide Slab Floor Coupling Reinforcement System has been investigated and tested on comparable wide slab floor elements at TU Eindhoven. Working with renowned partners, we have developed a repair system, including a calculation model. In addition to proven structural safety, the strengthening measure has little impact on the surrounding area and keeps disruption to a minimum.

The test specimens were designed and dimensioned identically to the slabs involved in the incident at the car park in Eindhoven.

The cause of the collapse of the slabs in the car park in Eindhoven was established before the investigation began.

The study at TU Eindhoven examined:

• Whether bonding an external carbon laminate could be used as a strengthening measure.
• Whether the load levels ultimately achieved would correspond to the failure loads predicted by theoretical calculations and computer simulations carried out in DIANA.

Various tests were carried out using different quantities of carbon laminates. In addition, slabs were preloaded with an initial debonding between the precast shell and the structural topping to simulate existing delamination. The conclusion of all these investigations is that the strengthening measure performs extremely well, and that the ultimate failure loads in the tests fully match those predicted by the computer models.

S&P Wide Slab Floor Coupling Reinforcement System:

  • S&P provides full technical support
  • System extensively tested
  • Various references available
  • No risk of drilling through existing reinforcement, concrete core activation systems or services
  • Can be used in occupied buildings
  • Dust-free system
  • Very little or no noise nuisance
  • Lightweight
  • Easy to install, with full training for installers

Fire protection

In most cases, fire protection for the carbon fibre reinforcement is not necessary. If fire resistance is required for the strengthening measure, S&P offers a standard solution providing 30, 60, 90 and 120 minutes of fire resistance.

Click here for the PDF version of the article

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectBouwMat
Share this article

Follow on Grond/Weg/Waterbouw Nederland

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.