BouwMat

Wide-Panel Floor Slab Shear Connection System

Wide-Panel Floor Slab Shear Connection System

S&P C-Laminate LM combined with S&P Resin 220HP epoxy adhesive is the ideal solution for potentially defective wide-panel floor slabs. The system has been fully tested and can be installed with very little disruption.

Following the collapse of the car park in Eindhoven, we brought together our international knowledge and experience and set out to find a suitable solution. As a manufacturer and supplier of carbon-fibre-based materials, we are close to the market and are an independent partner for all structural engineers.

Our S&P C-Laminate has been used successfully for 25 years in a wide range of strengthening works on concrete structures. Applications range from openings, voids and spans to reducing existing reinforcement (corrosion) in civil engineering structures. Our carbon-fibre reinforcement is also used in repairs to cantilevered balconies and galleries, and to strengthen masonry in earthquake-prone areas.

The S&P Wide-Panel Floor Slab Shear Connection System was investigated and tested on comparable wide-panel floor slab elements at TU Eindhoven. Working with renowned partners, we developed a repair system, including a calculation model. In addition to proven structural safety, the strengthening measure has little impact on the surroundings and minimises disruption.

The test specimens were designed and dimensioned identically to the slabs involved in the incident at the car park in Eindhoven.

The cause of the collapse of the slabs in the car park in Eindhoven was established before the investigation began.

The investigation at TU Eindhoven examined:

• Whether bonding an external carbon-fibre strip could provide a strengthening solution.
• Whether the loads ultimately achieved would match the failure loads predicted by theoretical calculations and computer simulations carried out in DIANA.

Various tests were carried out using different quantities of carbon-fibre strips. Some slabs were also preloaded with an initial debond between the precast shell and the compression layer to simulate existing delamination. The conclusion of all these investigations is that the strengthening measure performs extremely well, and that the ultimate failure loads recorded during the tests correspond exactly with the computer models.

S&P Wide-Panel Floor Slab Shear Connection System:

  • S&P provides full technical support
  • System extensively tested
  • Various references available
  • No risk of drilling through existing reinforcement, concrete core activation systems or services
  • Can be used in occupied buildings
  • Dust-free system
  • Very little to no noise nuisance
  • Lightweight
  • Easy to install, with full training for installers

Fire protection

In most cases, the carbon-fibre bonded reinforcement does not need fire protection. Where fire protection is required, S&P offers a standard solution providing 30, 60, 90 or 120 minutes of fire resistance.

Click here for the PDF version of the article

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectBouwMat
Share this article

Follow on Grond/Weg/Waterbouw Nederland

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.