S&P C-Laminate LM combined with S&P Resin 220HP epoxy adhesive is the solution for suspect precast floor slabs. The system has been fully tested and can be installed with very little disruption.

Following the collapse of the car park in Eindhoven, we pooled our international knowledge and experience and set out to find a suitable solution. As a manufacturer and supplier of carbon-fibre-based materials, we are close to the market and are an independent partner for all structural engineers.

Our S&P C-Laminate has been used successfully for 25 years in a wide range of concrete structure strengthening applications. These include openings, voids and spans, as well as reducing the effects of existing reinforcement corrosion in civil engineering structures. Our carbon-fibre reinforcement is also used in repairs to cantilevered balconies and access galleries, and in the strengthening of masonry in earthquake-prone areas.

The S&P Precast Floor Slab Coupling Reinforcement System has been investigated and tested on comparable precast floor slab elements at TU Eindhoven. Working with leading industry partners, we developed a repair system, including a calculation model. In addition to its proven structural safety, the strengthening measure has little impact on the surroundings and keeps disruption to a minimum.

The test specimens were identical in design and dimensions to the slabs involved in the incident at the car park in Eindhoven.

The cause of the collapse of the slabs in the car park in Eindhoven had been established before the investigation began.

The investigation at TU Eindhoven examined:

• Whether bonding an external carbon-fibre laminate could be used as a strengthening measure.
• Whether the loads ultimately achieved would match the theoretical and computer simulations carried out in DIANA, by comparing them with the actual failure loads.

Various tests were carried out using different quantities of carbon-fibre laminates. Some slabs were also preloaded, with an initial debonding between the precast slab and the concrete topping introduced to simulate existing delamination. The conclusion of all these investigations is that the strengthening measure performs excellently, and that the ultimate failure loads recorded during the tests correspond fully with the computer models.

S&P Precast Floor Slab Coupling Reinforcement System:

  • S&P provides full technical support
  • System extensively tested
  • Various references available
  • No risk of drilling through existing reinforcement, concrete core activation systems or pipes
  • Can be used in occupied buildings
  • Dust-free system
  • Very little to no noise disturbance
  • Lightweight
  • Easy to install, with full training for installers

Fire protection

In most cases, the carbon-fibre reinforcement does not need to be protected against fire. Where fire protection for the strengthening measure is required, S&P has a standard solution available for fire resistance periods of 30, 60, 90 and 120 min.

Click here for the PDF version of the article

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectNews
Share this article

Follow on Grond/Weg/Waterbouw Nederland

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.